Etelux Lab2000 Standard 2400 Single-sided Double-station Split-type Glove Box
Etelux Lab2000 Standard 1800 Single-sided Double-station Integrated Glove Box
Etelux Lab2000 Standard 1800 Single-sided Double-station Split-type Glove Box
The Lab2000 system includes a closed chamber, a set of (main and mini) antichamber, a rotary vane vacuum pump, and a set of circulating purification system integrated with a microcontroller operation panel. The inert gas purification system equipped with the standard Lab2000 system is equipped with a set of purification columns (fully automatic and renewable) to purify and maintain the atmosphere inside the glove box.
- 描述
- Product Size
- Accessories List
- Technical Parameters
- Order Information
- After-sales Service
- Document
- 用户评价 0

![]() |
![]() |
![]() |
![]() |
| Oxygen analyzer 1 pcs | Dew analyzer 1 pcs | Oil mist filter 1 pcs | Bellows hose 3 pcs |
![]() |
![]() |
![]() |
![]() |
| Gloves 4 pcs | Edward vacuum pump 1 pcs | Clamps 7 sets | Glove seal rings 8 pcs |
| Chamber | |
| Description | Material: Stainless steel 1.4301 (SUS type 304); Thickness 3 mm;Dimensions: 1800mm(70.8″)x 750mm(29.5″)x 900mm(35.4″) L x W x H |
| Volumn | 0.8 m³(28.2cu) |
| Front window | Panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional);Dimensions: 1735mm (68.3″) x 839mm (33.0″) L x H |
| Glove port | Hard aluminum alloy material or polyoxymethylene material (optional); Glove port diameter: 220 mm (8.7″); O-ring seal |
| Gloves | Material: Butyl rubber; Thickness: 0.4 mm or 0.8 mm (available for selection) |
| Filter | Outlet and inlet filters, filter rate<0.3μm |
| Illumination | LED lighting is located on the top of the front window |
| Leak rate | Final acceptance test according to the standard of leakage rate <0.05 vol% / h |
| GP20 Gas Purification System | |
| Description | Automatic removal of H2O and O2; single purification column system, automatic regeneration (optional GP200 double purification column); closed gas circulation line |
| Use voltage | AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (Available for selection) |
| Working gas | Working gas:N2、Ar 、He(purity≥99.999%);Regeneration gas:H2 accounts for 5% -10%, the rest is working gas (purity ≥99.999%) |
| Vacuum pump | Specifications: Rotary vane vacuum pump, equipped with oil mist filter, with gas ballast control; flow rate: 12 m³ /h (7 cfm), vacuum degree < 2 x 10-3 mbar (dry pump optional) |
| Circulation unit | Oil-free high-speed fan; air volume: 0-100 m³ / h (0-59 cfm) |
| Valve | Electromagnetic high vacuum valve |
| Leak rate | Final acceptance test according to the standard of leakage rate <0.05 vol% / h |
| Cleaning system | |
| Description | After setting the corresponding time and pressure, the system can automatically perform gas replacement in the chamber. |
| Analyzer | ||
| Oxygen analyzer | Size | 205 mm(8.1″) x 80 mm(3.1″) x 60 mm(2.4″)L x W x H |
| Measurement range | 0-1000 ppm | |
| Other oxygen transmitter | GE oxy.IQ™ Oxygen Transmitter | |
| Dew analyzer | Size | 205 mm(8.1″) x 80 mm(3.1″) x 60 mm(2.4″)L x W x H |
| Measurement range | 0-500 ppm | |
| Other watertransmitter | GE VeriDri™ Dew-Point Transmitter | |
| Solvent purification system | ||
| Leak rate | Material: Stainless steel 1.4301 (SUS type 304), thickness 3 mmInternal size: 220mm (8.7″) x 450mm (17.7″) Φ x HHigh-quality activated carbon | |
| Optional equipment | ||
| Refrigerator | Independent control system, integrated in the side panel of the chamber, temperature -35 ℃, volume 18L or 32L optional; main chamber 304 stainless steel sheet, 5 layers of variable compartments R404 environmentally friendly refrigerant, imported | |
| Heating chamber | The main antechamber is equipped with a heating system with a temperature of 200 ℃ and a temperature control of ± 1 ℃ | |
| Other instructions | ||
| Product certification | ISO9001 certification, CE certification, UL certification | |
| Warranty | One-year warranty period, lifetime maintenance | |
|
Application considerations |
For details, please refer to the instruction manual danger, warning, caution, etc |
|
| E | * | 1 | 2 | 3 | 4 | Instruction |
| Standardglove box | 1200 | Chamber size 1200mm(47.2″)×750mm(29.5″)×900mm(35.4″) L × W × H | ||||
| 1500 | Chamber size 1500mm(59.0″)×750mm(29.5″)×900mm(35.4″) L × W × H | |||||
| 1800 | Chamber size 1800mm(70.8″)×750mm(29.5″)×900mm(35.4″) L ×W × H | |||||
| 2400 | Chamber size 2400mm(94.5″)×750mm(29.5″)×900mm(35.4″) L × W × H | |||||
| Structural configuration | U | Standard integrated glove box | ||||
| S | Standard split glove box | |||||
| D | Equipped with operable double-sided glove box | |||||
| Function options | P | With automatic cleaning function, can quickly replace the gas in the chamber | ||||
| G | Quickly absorb the small amount of H2O, O2 ≤1ppm(including H2O, O2 analyzers) | |||||
| O | With organic solvent adsorption system, equipped with high-quality activated carbon | |||||
| Antichamber | A0 | Main antechamber 360mm(14.2″)×600mm(23.6″) φ × L | ||||
| A1 | Big antechamber 390mm(15.3″)×600mm(23.6″) φ × L | |||||
| A2 | Small antechamber 150mm(5.9″)×330mm(13.0″) φ × L | |||||
| A3 | Square chamber 400mm(15.7″)×300mm(11.8″)×300mm(11.8″) L × W × H | |||||
| Other function options | FW | With openable front window | ||||
| 18F | With refrigerator volume 18L, temperature is -36 ℃ | |||||
| 32F | With refrigerator volume 32L, temperature is -36 ℃ | |||||
* is basic mandatory options, 1, 2, 3, 4 are optional order numbers, which can be configured according to needs. If you have special order, you can contact us.
Examples of order numbers:
①E-1200UPGO, which means an integrated single station 1200mm(47.2″) glove box, with automatic cleaning, H2O and O2 purification system, solvent adsorption system;
②E-18 00SDPG-A3, which means split 1800mm(70.8″) double-sided four-station glove box, with automatic cleaning, H2O and O2 purification system, and a square antechamber.
| Etelux “365 days worry-free”, value-added warranty service |
| “365 days worry-free ” extended warranty service value, extended warranty service value, all-day, whole process, save more money, more timely, more reassuring and more convenient, controllable maintenance cost, professional maintenance service |
| ★ The whole process: one-stop repair, maintenance and training services, and establish a complete user file. |
| ★ Save more money: |
| 1) After purchasing the extended warranty service, you do not need to pay any additional fees for equipment maintenance (except consumables); |
| 2) Free value-added services, timely replacement of parts you usually do not pay attention to repair, eliminate hidden dangers, and ensure that the equipment has been in good condition; |
| 3) More favorable hardware upgrades to meet your higher demand for equipment; |
| 4) Buy consumables more preferentially. |
| ★ More timely:After you choose extend the warranty service, the company will store commonly used modular accessories for engineers. Engineers can replace faulty modules efficiently and in a timely manner, shorten the maintenance cycle, and make your production work smoother and more efficient, and make high profits for you. |
| ★ More reassuring:After the free warranty period of 1 year, the device will no longer enjoy the free warranty service. After purchasing the extended warranty service, you can continue to enjoy the free warranty. We will regularly return to the use of the device to provide you with quality and perfect Equipment warranty service, to avoid your worries. |
| ★ More convenient:You only need to call the customer service hotline of Etelux: 400-086-8156. The 400 call center will serve you 24 hours, and we can meet all your needs immediately. |
| ★ Controllable maintenance costs:If the extended warranty service is not purchased, the maintenance cost will be charged according to the faulty equipment and the fault situation. The enterprise cannot control the maintenance cost of the equipment; after purchasing the extended warranty service, the maintenance cost can be controlled, and it becomes a budgetary investment, which can greatly reduce equipment maintenance risks caused by increased costs. |
| ★ Professional maintenance services: Let our service team provides you with more professional support and work together to create a better future! |
Thank you for downloading this electronic product catalog file. This file is part of the printed Etelux catalog. Once there is a new or revised version, this electronic file will be updated accordingly, and the electronic file will be updated more timely than the printed version. If you need more help, please contact us.
16
















评价
目前还没有评价